FILTRATION & PERFORMANCE

The UCE‑9000 & UCE‑11 Citric Acid Cleaning Cartridge is essential in areas with hard water or mineral-rich sources. Specifically designed for Tyent’s UCE‑9000 and UCE‑11 under-counter ionizer models, this single-use cleaning cartridge:

  • Descales internal plates by dissolving mineral buildup.
  • Prevents future scaling, helping maintain consistent water quality and ensuring the longevity of your ionizer.

ADD-ONS & COMPATIBLE OPTIONS

To keep your entire water system clean and efficient, consider these complementary options:

  • Tyent Scale Remover Device — reusable option for deeper cleaning in less than 30 minutes.
  • Cell Safe™ Anti-Scale Pre-Filter — installs before your ionizer to prevent scale formation from the start.
  • Ultra PLUS Filters for UCE‑9000 & UCE‑11 — high-performance replacement filters offering .01-micron multistage filtration to remove contaminants like chlorine, chloramines, heavy metals, and more. Equivalent to medical-grade dialysis filters, with an approximate 951-gallon or 6-month lifespan.

USAGE

Simple to integrate and highly effective, here’s how to use it:

  1. Power off your ionizer and turn off the water supply.
  2. Remove the second filter from the housing.
  3. Insert the Citric Acid Cleaning Cartridge—do not over-tighten.
  4. Turn on the unit and water, then run H₂O CLEAN mode for 30 seconds only—no other settings.
  5. Let the unit sit idle for 3 hours.
  6. Optional: Repeat steps 4 and 5 up to 3 times for deep cleaning.
  7. Replace the cartridge with your regular filter or a new replacement.
  8. Run the H₂O cycle for 3 minutes to flush the system.
  9. Check that pH levels and flow return to normal.

Recommended frequency: every 6–12 months or as needed based on your water quality and usage.